Bolted Joint Design Check (Preload, Separation, Proof and Fatigue)

Does this bolt size and tightening torque keep the joint closed and the bolt safe under the working load?

Complete check of a preloaded tension joint: stress area, bolt and member (frustum) stiffness, joint constant, preload and tightening torque from the target share of proof load, preload scatter from the nut factor tolerance, and factors against separation, exceeding proof load and fatigue (Goodman) under a load cycling from zero to the working value.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Bolt
Nominal diametermmNominal bolt diameter.
Thread pitchmmThread pitch.
Proof strengthMPaProof strength of the property class (from the bolt standard).
Tensile strengthMPaMinimum tensile strength.
Endurance limit of the threaded boltMPaFully corrected endurance limit of the threaded bolt (rolled or cut threads, from fatigue data).
Bolt modulusGPaElastic modulus of the bolt.
Joint
Grip lengthmmTotal thickness clamped.
Threaded length within the gripmmLength of thread inside the grip.
Member modulusGPaElastic modulus of the clamped members (the frustum estimate assumes one material).
Tightening and load
Target preload (share of proof load)%Preload as a share of proof load (75% is common for reusable joints).
Nut factorNominal nut factor for the finish and lubrication.
Nut factor scatter (±)%Uncertainty in the nut factor, which scatters the preload for a given torque.
Working tension load per boltkNExternal tension load per bolt, cycling from zero.
Required factor (separation and fatigue)Factor you require against separation and fatigue.

What each input means

Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.

Bolt

What this means: Nominal diameter
Illustration: Nominal diameterA screw-thread profile with crests and roots, the pitch from crest to crest and the major and minor diameters, for Nominal diameter.pitchmajorminordExample: 12 mmNominal diameter
What it is
The nominal (major) diameter of the bolt thread, the M size for a metric bolt, used for the shank area and the tightening torque.
Units and format
Enter a number in mm: millimetres. The form accepts 0.000001 mm to 200 mm. Required: the tool does not calculate until every input is valid.
Example
The form opens with 12 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Thread pitch
Illustration: Thread pitchA screw-thread profile with crests and roots, the pitch from crest to crest and the major and minor diameters, for Thread pitch.pitchmajorminorPExample: 1.75 mmThread pitch
What it is
The axial distance between adjacent thread crests of the bolt, which sets the tensile stress area.
Units and format
Enter a number in mm: millimetres. The form accepts 0.000001 mm to 10 mm. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1.75 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Check whether the bolt is coarse or fine pitch; a finer pitch gives a larger stress area.
What this means: Proof strength
Illustration: Proof strengthA test bar pulled from both ends: stress Proof strength is the force carried by each square millimetre of its cross-section.Spstress = force ÷ areaExample: 600 MPaProof strength
What it is
The minimum proof strength of the bolt’s property class, the stress it must withstand without permanent set, from the bolt standard.
Units and format
Enter a number in MPa: megapascals (1 MPa = 1 N/mm²). The form accepts 0.000001 MPa to 2000 MPa. Required: the tool does not calculate until every input is valid.
Example
The form opens with 600 MPa as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Preload and tightening torque rise in direct proportion to it.
What this means: Tensile strength
Illustration: Tensile strengthA test bar pulled from both ends: stress Tensile strength is the force carried by each square millimetre of its cross-section.Sutstress = force ÷ areaExample: 830 MPaTensile strength
What it is
The minimum tensile strength of the bolt’s property class, used in the Goodman fatigue check.
Units and format
Enter a number in MPa: megapascals (1 MPa = 1 N/mm²). The form accepts 0.000001 MPa to 2500 MPa. Required: the tool does not calculate until every input is valid.
Example
The form opens with 830 MPa as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Endurance limit of the threaded bolt
Illustration: Endurance limit of the threaded boltA test bar pulled from both ends: stress Endurance limit of the threaded bolt is the force carried by each square millimetre of its cross-section.Sestress = force ÷ areaExample: 129 MPaEndurance limit of the threaded bolt
What it is
The fully corrected endurance limit of the threaded bolt, allowing for rolled or cut threads, size and reliability, from fatigue data for the bolt.
Units and format
Enter a number in MPa: megapascals (1 MPa = 1 N/mm²). The form accepts 0.000001 MPa to 1000 MPa. Required: the tool does not calculate until every input is valid.
Example
The form opens with 129 MPa as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Use the value for the threaded bolt, not the endurance limit of plain material.
What this means: Bolt modulus
Illustration: Bolt modulusA stress against strain graph whose straight starting slope is the stiffness value Bolt modulus.stressstrainEbExample: 207 GPaBolt modulus
What it is
The elastic modulus of the bolt material, used to work out the bolt’s stiffness.
Units and format
Enter a number in GPa: gigapascals (1 GPa = 1000 MPa). The form accepts 0.000001 GPa to 500 GPa. Required: the tool does not calculate until every input is valid.
Example
The form opens with 207 GPa as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
In GPa, not MPa.

Joint

What this means: Grip length
Illustration: Grip lengthThe cross-section of a plate or wall with a dimension across its thickness, marking Grip length.lsection through the materialExample: 30 mmGrip length
What it is
The total thickness of the parts clamped between the bolt head and the nut or tapped thread.
Units and format
Enter a number in mm: millimetres. The form accepts 0.000001 mm to 2000 mm. Required: the tool does not calculate until every input is valid.
Example
The form opens with 30 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Include washers; do not include the head or nut height.
What this means: Threaded length within the grip
Illustration: Threaded length within the gripA bar with a dimension line and arrows from one end to the other, marking the length Threaded length within the grip.LtExample: 10 mmThreaded length within the grip
What it is
The length of threaded shank lying inside the grip, between the clamped faces; the rest of the grip is plain shank.
Units and format
Enter a number in mm: millimetres. The form accepts 0 mm to 2000 mm. Required: the tool does not calculate until every input is valid.
Example
The form opens with 10 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
It cannot exceed the grip; use the full grip if the bolt is threaded right up to the head.
What this means: Member modulus
Illustration: Member modulusA stress against strain graph whose straight starting slope is the stiffness value Member modulus.stressstrainEmExample: 207 GPaMember modulus
What it is
The elastic modulus of the clamped parts, used in the 30° frustum estimate of joint stiffness.
Units and format
Enter a number in GPa: gigapascals (1 GPa = 1000 MPa). The form accepts 0.000001 GPa to 500 GPa. Required: the tool does not calculate until every input is valid.
Example
The form opens with 207 GPa as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
The frustum estimate assumes all clamped parts are one material; mixed-material joints need a fuller stiffness method.

Tightening and load

What this means: Target preload (share of proof load)
Illustration: Target preload (share of proof load)A bar of 100 parts with the share marked; Target preload (share of proof load) is that share out of 100. The bar follows the value you type.0 %100 %Example: 70%Target preload (share of proof load)
What it is
The preload you aim for, as a percentage of the bolt’s proof load (proof strength times tensile stress area).
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 10% to 95%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 70% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Preload and torque rise in proportion; a higher preload improves the separation factor but lowers the proof margin.
What this means: Nut factor
Illustration: Nut factorTwo bars: a base value and the same value multiplied by Nut factor, the factor.base valuewith factorKExample: 0.2Nut factor
What it is
The nut factor in T = K F d, which relates tightening torque to preload and depends on thread finish and lubrication.
Units and format
Enter a plain number with no unit. The form accepts 0.05 to 0.5. Required: the tool does not calculate until every input is valid.
Example
The form opens with 0.2 as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Tightening torque is directly proportional to the nut factor.
Get it right
Take it from the fastener or lubricant supplier, or from torque–tension tests for your finish and lubricant.
What this means: Nut factor scatter (±)
Illustration: Nut factor scatter (±)A bar of 100 parts with the share marked; Nut factor scatter (±) is that share out of 100. The bar follows the value you type.0 %100 %Example: 25%Nut factor scatter (±)
What it is
The uncertainty in the nut factor, as a ± percentage, which spreads the preload actually achieved at the set torque.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 0% to 60%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 25% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
More scatter lowers the minimum preload (separation check) and raises the maximum preload (proof and fatigue checks).
What this means: Working tension load per bolt
Illustration: Working tension load per boltA block with an arrow pushing on it; the arrow is the force Working tension load per bolt.PExample: 10 kNWorking tension load per bolt
What it is
The external tensile working load on one bolt, cycling from zero, after the joint load has been shared between the bolts.
Units and format
Enter a number in kN: kilonewtons (1 kN = 1000 N). The form accepts 0 kN to 100000 kN. Required: the tool does not calculate until every input is valid.
Example
The form opens with 10 kN as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Load per bolt, not total joint load: divide the total by the number of bolts where it is shared evenly.
What this means: Required factor (separation and fatigue)
Illustration: Required factor (separation and fatigue)Two bars: a base value and the same value multiplied by Required factor (separation and fatigue), the factor.base valuewith factornExample: 1.5Required factor (separation and fatigue)
What it is
The minimum factor you require against joint separation and against fatigue, from your design code or company practice.
Units and format
Enter a plain number with no unit. The form accepts 1 to 10. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1.5 as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
It does not change the bolt loads; it sets the pass or fail checks for separation and fatigue.

Method and formulas

  1. A_t = π ÷ 4 (d − 0.9382 P)²; k_b from the shank and threaded lengths; k_m by the 30° frustum: 0.5774 π E d ÷ 2 ln[5 (0.5774 l + 0.5 d) ÷ (0.5774 l + 2.5 d)].
  2. C = k_b ÷ (k_b + k_m); F_i = share × S_p A_t; torque T = K F_i d; scatter gives F_i ÷ (1 ± scatter).
  3. Separation factor = F_i,min ÷ [(1 − C) P]; proof factor = (S_p A_t − F_i,max) ÷ C P.
  4. Fatigue (Goodman): n_f = S_e (S_ut − σ_i) ÷ [σ_a (S_ut + S_e)], σ_a = C P ÷ 2A_t, σ_i = F_i,max ÷ A_t.
  5. Example: an M12 bolt at 70% of proof needs 84.941 N·m and holds 3.6253 times the separation load.

Limitations

  • Concentric tension joint; prying, bending and thermal loads are excluded.
  • Frustum stiffness assumes members of one material wider than about three bolt diameters.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Choose bolt size, grade and torque for a joint
  • Check a joint after a load increase
  • Decide whether torque control is good enough

Who it is for

  • Design engineers
  • Assembly engineers
  • Maintenance engineers

What you get

  • Stress area, stiffnesses and joint constant
  • Preload range and tightening torque
  • Factors against separation, proof and fatigue

Interpreting the result

  • If separation fails, raise preload or use more bolts; if fatigue fails, use rolled threads, a longer bolt or a stiffer joint.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 1521–1536. Topic reference; no source tables or recommended settings are reproduced.

Learn the Concepts Behind This Tool

These BIZOMAT Library readings explain the method this tool uses, with worked examples.

BIZOMAT tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.