Column Buckling (Euler and Johnson)

What load will buckle this column or strut, and is the safety factor enough?

Critical buckling load of a straight, centrally loaded column using Euler’s formula for slender members and the J.B. Johnson parabola for intermediate ones, with the safety factor against an applied load.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Elastic modulusGPaElastic modulus from the material data sheet or an approved materials database (steel is typically about 200 GPa).
Yield strengthMPaMinimum yield strength from the material certificate or specification, not a typical value.
Cross-section areamm²Area of the section, from a section table or the section properties calculator.
Least second moment of areamm⁴Smallest second moment of area of the section (the weak axis).
Unsupported lengthmmLength between points that are held against sideways movement.
Effective length factor KTheoretical values: 1.0 pinned–pinned, 0.5 fixed–fixed, 0.7 fixed–pinned, 2.0 fixed–free. Design codes often use larger values for real end conditions.
Applied axial loadNLargest compressive load on the member.
Required safety factorFactor of safety required by your design code, customer specification or company standard.

What each input means

Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.

What this means: Elastic modulus
Illustration: Elastic modulusA stress against strain graph whose straight starting slope is the stiffness value Elastic modulus.stressstrainEExample: 200 GPaElastic modulus
What it is
The elastic modulus (Young’s modulus) of the column material: its stiffness in tension and compression, from the material data sheet.
Units and format
Enter a number in GPa: gigapascals (1 GPa = 1000 MPa). The form accepts 0.000001 GPa to 1000 GPa. Required: the tool does not calculate until every input is valid.
Example
The form opens with 200 GPa as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Enter GPa, not MPa: 1 GPa is 1000 MPa.
What this means: Yield strength
Illustration: Yield strengthA test bar pulled from both ends: stress Yield strength is the force carried by each square millimetre of its cross-section.Systress = force ÷ areaExample: 250 MPaYield strength
What it is
The minimum yield strength of the column material, the stress at which it starts to deform permanently, from the material certificate or specification.
Units and format
Enter a number in MPa: megapascals (1 MPa = 1 N/mm²). The form accepts 0.000001 MPa to 5000 MPa. Required: the tool does not calculate until every input is valid.
Example
The form opens with 250 MPa as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Use the specified minimum, not a typical test value.
What this means: Cross-section area
Illustration: Cross-section areaA shaded shape whose enclosed surface is the area Cross-section area.AenclosedsurfaceExample: 1000 mm²Cross-section area
What it is
The cross-section area of the column or strut, the area of material cut across its length, from a section table or a section properties calculation.
Units and format
Enter a number in mm²: square millimetres. The form accepts 0.000001 mm² to 100000000 mm². Required: the tool does not calculate until every input is valid.
Example
The form opens with 1000 mm² as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Use the net area of the actual section, in mm².
What this means: Least second moment of area
Illustration: Least second moment of areaThe cross-section of a beam with its neutral axis; Least second moment of area describes how the section’s area is spread around that axis.neutral axisIExample: 400000 mm⁴Least second moment of area
What it is
The smallest second moment of area of the section, about its weak axis. It describes how the material is spread from that axis and resists bending sideways.
Units and format
Enter a number in mm⁴: millimetres to the fourth power (second moment of area). The form accepts 0.000001 mm⁴ or more. Required: the tool does not calculate until every input is valid.
Example
The form opens with 400000 mm⁴ as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Use the least value of the section; a column buckles about its weakest axis unless that direction is braced.
What this means: Unsupported length
Illustration: Unsupported lengthA bar with a dimension line and arrows from one end to the other, marking the length Unsupported length.LExample: 2000 mmUnsupported length
What it is
The length of the column between the points that are held against sideways movement.
Units and format
Enter a number in mm: millimetres. The form accepts 0.000001 mm to 1000000 mm. Required: the tool does not calculate until every input is valid.
Example
The form opens with 2000 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
In the slender (Euler) range the buckling load falls with the square of the length.
Get it right
Measure between actual lateral supports, not the overall member length if it is braced partway.
What this means: Effective length factor K
Illustration: Effective length factor KTwo bars: a base value and the same value multiplied by Effective length factor K, the factor.base valuewith factorKExample: 1Effective length factor K
What it is
The effective length factor: a multiplier on the unsupported length that accounts for how the ends are held (pinned, fixed or free).
Units and format
Enter a plain number with no unit. The form accepts 0.1 to 5. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1 as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
A larger factor increases the slenderness and lowers the buckling load.
Get it right
Design codes often use larger values than the theoretical ones for real end conditions; use your code’s value.
What this means: Applied axial load
Illustration: Applied axial loadA block with an arrow pushing on it; the arrow is the force Applied axial load.PExample: 50000 NApplied axial load
What it is
The largest compressive axial load the member must carry along its length.
Units and format
Enter a number in N: newtons. The form accepts 0.000001 N or more. Required: the tool does not calculate until every input is valid.
Example
The form opens with 50000 N as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
The safety factor falls in proportion as this load rises.
Get it right
Include all load cases that put the member in compression and use the largest.
What this means: Required safety factor
Illustration: Required safety factorTwo bars: a base value and the same value multiplied by Required safety factor, the factor.base valuewith factornExample: 2.5Required safety factor
What it is
The minimum ratio of critical buckling load to applied load that the member must achieve, from your design code, customer specification or company standard.
Units and format
Enter a plain number with no unit. The form accepts 1 to 20. Required: the tool does not calculate until every input is valid.
Example
The form opens with 2.5 as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
This is a requirement you set; the tool only compares the calculated factor with it.

Method and formulas

  1. r = √(I ÷ A); slenderness λ = K L ÷ r; transition C_c = π√(2E ÷ S_y).
  2. Euler (λ ≥ C_c): σ_cr = π²E ÷ λ².
  3. Johnson (λ < C_c): σ_cr = S_y − (S_y λ ÷ 2π)² ÷ E.
  4. P_cr = σ_cr × A; safety factor = P_cr ÷ P.
  5. Example: the default strut has λ = 100, below C_c = 125.66, so Johnson gives P_cr = 170.84 kN and a factor of 3.4169.

Limitations

  • Straight, centrally loaded, prismatic members; eccentricity and initial crookedness reduce capacity (see the eccentric column method or your code).
  • Local buckling of thin walls and lateral-torsional buckling are not checked.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Check push rods, cylinder rods, props and frame members in compression
  • Choose a section to resist buckling
  • Compare end fixity options

Who it is for

  • Design engineers
  • Structural and mechanical engineers
  • Engineering students

What you get

  • Slenderness ratio and transition slenderness
  • Method used (Euler or Johnson)
  • Critical load
  • Safety factor

Interpreting the result

  • Structural steelwork must also be checked to the applicable code (e.g. AS 4100), which includes imperfection factors.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 281–287. Topic reference; no source tables or recommended settings are reproduced.

Learn the Concepts Behind This Tool

These BIZOMAT Library readings explain the method this tool uses, with worked examples.

BIZOMAT tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.

Open the Column Buckling (Euler and Johnson) calculator