Air Compressor Power

What shaft power does it take to compress this air flow to this pressure?

Theoretical isothermal and adiabatic power to compress a flow of free air in one or more intercooled stages, and the shaft power with an overall efficiency.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Air flow (free air delivery)m³/minFlow of air measured at inlet conditions (free air delivery).
Discharge pressure (gauge)barDischarge pressure at the compressor outlet.
Inlet pressure (absolute)barAbsolute inlet pressure (1.013 bar at sea level; lower at altitude or with inlet filter loss).
Compression stages (intercooled)stagesNumber of stages with perfect intercooling and equal pressure ratios.
Ratio of specific heats1.4 for air.
Overall efficiency (adiabatic to shaft)%Ratio of theoretical adiabatic power to shaft power, from the compressor maker (often 65–85%).

What each input means

Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.

What this means: Air flow (free air delivery)
Illustration: Air flow (free air delivery)A pipe with liquid or gas moving through it; Air flow (free air delivery) is the volume that passes per unit of time.QExample: 10 m³/minAir flow (free air delivery)
What it is
The volume of air the compressor delivers each minute, expressed at its inlet conditions, also called free air delivery.
Units and format
Enter a number in m³/min: cubic metres per minute. The form accepts 0.000001 m³/min to 100000 m³/min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 10 m³/min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
All powers rise in direct proportion.
Get it right
Use free air delivery, not the compressed volume at outlet pressure.
What this means: Discharge pressure (gauge)
Illustration: Discharge pressure (gauge)A pressure gauge whose needle moves with Discharge pressure (gauge); the needle follows the value you type.p₂Example: 7 barDischarge pressure (gauge)
What it is
The pressure at the compressor outlet, measured as gauge pressure.
Units and format
Enter a number in bar: bar (1 bar = 100 kPa). The form accepts 0.000001 bar to 1000 bar. Required: the tool does not calculate until every input is valid.
Example
The form opens with 7 bar as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
A higher discharge pressure raises power.
Get it right
Enter gauge pressure from the outlet gauge; the tool adds standard atmospheric pressure itself.
What this means: Inlet pressure (absolute)
Illustration: Inlet pressure (absolute)A pressure gauge whose needle moves with Inlet pressure (absolute); the needle follows the value you type.p₁Example: 1.013 barInlet pressure (absolute)
What it is
The absolute pressure of the air entering the compressor: local atmospheric pressure, reduced by altitude and inlet filter loss.
Units and format
Enter a number in bar: bar (1 bar = 100 kPa). The form accepts 0.000001 bar to 100 bar. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1.013 bar as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
A lower inlet pressure raises the pressure ratio for the same discharge.
Get it right
Enter absolute pressure, not gauge. Note that the discharge pressure is converted using standard atmosphere.
What this means: Compression stages (intercooled)
Illustration: Compression stages (intercooled)A row of identical items being counted; Compression stages (intercooled) is how many there are.NExample: 1 stagesCompression stages (intercooled)
What it is
The number of compression stages with intercooling between them, assumed to share the pressure ratio equally.
Units and format
Enter a number in stages: stages. The form accepts 1 stages to 6 stages. Use a whole number. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1 stages as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
More intercooled stages lower the adiabatic power.
Get it right
Count stages in series, not compressors in parallel.
What this means: Ratio of specific heats
Illustration: Ratio of specific heatsA number line with a marker at the value of Ratio of specific heats, between its lowest and highest accepted values.1.011.67kExample: 1.4Ratio of specific heats
What it is
The ratio of the gas’s specific heat at constant pressure to that at constant volume, a property of the gas being compressed.
Units and format
Enter a plain number with no unit. The form accepts 1.01 to 1.67. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1.4 as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Take it from gas property data for the gas compressed; it is not an efficiency.
What this means: Overall efficiency (adiabatic to shaft)
Illustration: Overall efficiency (adiabatic to shaft)Input on the left and useful output on the right with the loss split off; Overall efficiency (adiabatic to shaft) is output divided by input.inputuseful outputlossηExample: 75%Overall efficiency (adiabatic to shaft)
What it is
The theoretical adiabatic power divided by the actual shaft power, covering compressor losses, from the compressor maker’s data.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 1% to 100%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 75% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
A lower efficiency raises shaft power and specific power.
Get it right
Type the percentage itself; motor losses are not included in shaft power.

Method and formulas

  1. Isothermal: P = p₁ Q ln(p₂ ÷ p₁).
  2. Adiabatic with N stages: P = N × k/(k − 1) × p₁ Q [(p₂ ÷ p₁)^((k − 1)/(N k)) − 1].
  3. Shaft power = adiabatic ÷ efficiency; specific power = shaft kW ÷ flow (m³/min).
  4. Example: 10 m³/min to 7 bar g in one stage needs about 63.475 kW at the shaft.

Limitations

  • Theoretical power with an overall efficiency; real compressors also lose energy at part load and in dryers.
  • Moisture in the air is ignored.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Estimate compressor motor size for a demand
  • Compare single and two-stage compression
  • Estimate specific power for energy studies

Who it is for

  • Maintenance engineers
  • Energy and utilities managers
  • Design engineers

What you get

  • Pressure ratio
  • Isothermal power
  • Adiabatic power
  • Shaft power and specific power

Interpreting the result

  • Compare specific power with maker data (kW per m³/min) to judge an existing compressor.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 3032–3041. Topic reference; no source tables or recommended settings are reproduced.

Learn the Concepts Behind This Tool

These BIZOMAT Library readings explain the method this tool uses, with worked examples.

BIZOMAT tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.

Open the Air Compressor Power calculator