Furnace Wall Design (Layers, Convection and Radiation from the Surface)
What outside surface temperature and heat loss will this layered furnace wall have, are the layer interfaces within their service temperatures, and what does the loss cost?
Heat loss through a layered furnace or oven wall with the outside surface losing heat by both convection and radiation: the surface temperature found by iteration so that conduction through the layers equals convection plus radiation (radiation as the radiant heat tool), the heat flux and loss for the wall area, the temperature at each interface (as the wall heat loss tool with the combined surface coefficient), the annual energy cost, and checks against the surface touch limit and the service limit of the insulating layer.
Open the calculatorRuns in your browser. No account needed.
How this tool works
Inputs, units and where to find them
| Input | Unit | Typical source |
|---|---|---|
| Hot face temperature | °C | Temperature of the hot face of the lining. |
| Ambient temperature | °C | Air temperature outside the furnace. |
| Layers (hot face first) | ||
| Layer 1 thickness | mm | Thickness of the hot-face layer (refractory brick or castable). |
| Layer 1 conductivity | W/m·K | Conductivity of layer 1 at its mean temperature. |
| Layer 2 thickness | mm | Thickness of the insulating layer. |
| Layer 2 conductivity | W/m·K | Conductivity of layer 2 at its mean temperature. |
| Layer 3 thickness (shell) | mm | Thickness of the steel shell (0 if none). |
| Layer 3 conductivity | W/m·K | Conductivity of the shell. |
| Outside surface | ||
| Convection coefficient | W/m²·K | Natural convection coefficient at the outer surface (about 5–10 indoors). |
| Surface emissivity | Emissivity of the outer surface (about 0.8 painted or oxidised steel). | |
| Wall area | m² | Area of wall. |
| Largest surface temperature | °C | Highest outside surface temperature you allow. |
| Service limit at the layer 1–2 interface | °C | Highest temperature the insulating layer may see (its service limit). |
| Hours per year | h | Hours per year at temperature. |
| Energy price | $/kWh | Energy price. |
What each input means
Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.
What this means: Hot face temperature
- What it is
- The temperature at the inside (hot) face of the lining, the face exposed to the furnace atmosphere.
- Units and format
- Enter a number in °C: degrees Celsius. The form accepts 0.000001 °C to 2000 °C. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 900 °C as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Ambient temperature
- What it is
- The temperature of the air surrounding the outside of the furnace.
- Units and format
- Enter a number in °C: degrees Celsius. The form accepts -50 °C to 60 °C. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 25 °C as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Layers (hot face first)
What this means: Layer 1 thickness
- What it is
- The thickness of the first layer, the one facing the furnace heat, such as refractory brick or castable.
- Units and format
- Enter a number in mm: millimetres. The form accepts 0 mm to 2000 mm. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 115 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Layer 1 conductivity
- What it is
- The thermal conductivity of the hot-face material at its mean working temperature, from the refractory supplier.
- Units and format
- Enter a number in W/m·K: W/m·K. The form accepts 0.01 W/m·K to 100 W/m·K. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 1.2 W/m·K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Layer 2 thickness
- What it is
- The thickness of the second layer, normally the insulation behind the hot face.
- Units and format
- Enter a number in mm: millimetres. The form accepts 0 mm to 2000 mm. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 230 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Layer 2 conductivity
- What it is
- The thermal conductivity of the insulating layer at its mean working temperature, from the supplier data sheet.
- Units and format
- Enter a number in W/m·K: W/m·K. The form accepts 0.01 W/m·K to 100 W/m·K. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 0.15 W/m·K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Layer 3 thickness (shell)
- What it is
- The thickness of the outer steel shell or casing; zero if there is no shell.
- Units and format
- Enter a number in mm: millimetres. The form accepts 0 mm to 200 mm. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 6 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Layer 3 conductivity
- What it is
- The thermal conductivity of the outer shell or casing material, from material data.
- Units and format
- Enter a number in W/m·K: W/m·K. The form accepts 0.01 W/m·K to 400 W/m·K. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 50 W/m·K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Outside surface
What this means: Convection coefficient
- What it is
- The natural convection heat transfer coefficient between the outer wall surface and the surrounding air.
- Units and format
- Enter a number in W/m²·K: watts per square metre per kelvin. The form accepts 1 W/m²·K to 100 W/m²·K. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 8 W/m²·K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
- Get it right
- Convection only; the tool adds radiation separately from the emissivity.
What this means: Surface emissivity
- What it is
- The emissivity of the outer surface, which sets how much heat it radiates to the surroundings.
- Units and format
- Enter a plain number with no unit. The form accepts 0.05 to 1. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 0.8 as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
- Get it right
- A fraction from 0 to 1, set by the surface finish and paint.
What this means: Wall area
- What it is
- The outside area of furnace wall built with this lining, used to turn heat flux into total heat loss.
- Units and format
- Enter a number in m²: square metres. The form accepts 0.000001 m² to 100000 m². Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 10 m² as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Largest surface temperature
- What it is
- The highest outside surface temperature you allow, for personnel protection or for equipment near the furnace.
- Units and format
- Enter a number in °C: degrees Celsius. The form accepts 0.000001 °C to 300 °C. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 70 °C as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
- Get it right
- Check your workplace safety requirements for touch temperatures.
What this means: Service limit at the layer 1–2 interface
- What it is
- The service temperature limit of the insulating layer, compared with the temperature where it meets the hot-face layer.
- Units and format
- Enter a number in °C: degrees Celsius. The form accepts 0.000001 °C to 2000 °C. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 1000 °C as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Hours per year
- What it is
- The hours per year the furnace runs at this temperature, used for the annual energy and cost.
- Units and format
- Enter a number in h: hours. The form accepts 0.000001 h to 8784 h. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with 4000 h as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Energy price
- What it is
- What you pay per kilowatt-hour of the fuel or electricity that heats the furnace.
- Units and format
- Enter a number in $/kWh: money per kilowatt-hour. The form accepts $0/kWh to $10/kWh. Required: the tool does not calculate until every input is valid.
- Example
- The form opens with $0.08/kWh as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
- Get it right
- The tool costs the heat lost, not fuel bought; for fired furnaces divide the fuel price by the burner efficiency.
Method and formulas
- Conduction resistance R = Σ t ÷ k per square metre; flux q = (T_hot − T_s) ÷ R.
- At the surface q = h_c (T_s − T_a) + ε σ (T_s⁴ − T_a⁴) (radiation as the radiant heat tool); solve for T_s by bisection.
- Interface temperatures fall by q × t ÷ k across each layer (as the wall heat loss tool with the combined coefficient).
- Loss = q × area; energy = loss × hours.
- Example: the shell runs at 62.288 °C, losing 514.16 W/m² (5.1416 kW); the insulation sees 850.73 °C.
Limitations
- Constant conductivities; real refractories vary strongly with temperature.
- Steady state; heat stored in the lining during start-up is not included.
- Example values are illustrations. Replace them with values for your actual task.
Typical uses
- Design a refractory and insulation lining
- Check a furnace shell surface for burn risk
- Estimate the running cost of wall losses
Who it is for
- Furnace engineers
- Plant engineers
- Energy managers
What you get
- Surface temperature, flux and heat loss
- Interface temperatures
- Annual energy cost and checks
Interpreting the result
- Most of the temperature drop should occur in the insulating layer; the brick protects it from the hot face.
References
- Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 371–378. Topic reference; no source tables or recommended settings are reproduced.
Learn the Concepts Behind This Tool
These BIZOMAT Library readings explain the method this tool uses, with worked examples.
Method explained here · BIZOMAT original book
Where the heat goes: available heat and the furnace load
What it covers: Follow a gas furnace's fuel into the load, the walls and the flue, calculate available heat from flue temperature and excess air, and plan a load's fuel, time and cost.
BIZOMAT tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.
Open the Furnace Wall Design (Layers, Convection and Radiation from the Surface) calculator