BIZOMAT MAKEOS · Hydraulics

Pump Operating Point on the System Curve

Where will this centrifugal pump actually run on my system, how efficiently, and what speed gives the flow I want?

Operating point of a centrifugal pump on a pipe system: a quadratic pump curve through shut-off head and the best-efficiency point, a system curve from static head and one known duty point, their intersection (flow, head), efficiency there from a parabolic efficiency curve, absorbed power, the position relative to the best-efficiency flow, and the speed (by the affinity laws) that gives a target flow.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Pump at rated speed
Shut-off headmHead at zero flow from the pump curve.
Best-efficiency flowL/minFlow at the best-efficiency point (BEP).
Head at best efficiencymHead at the BEP.
Best efficiency%Efficiency at the BEP.
Rated speedrpmSpeed the curve applies to.
System
Static head (lift plus pressure difference)mStatic head of the system: level difference plus pressure difference as head.
Known system flowL/minA flow at which the system head is known (from a pipe loss calculation).
System head at that flowmTotal system head at that flow.
Liquid densitykg/m³Liquid density.
Target flow (for the speed change)L/minFlow you want; the tool finds the pump speed that gives it.

What each input means

Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.

Pump at rated speed

What this means: Shut-off head
Illustration: Shut-off headA block with a vertical dimension line from its base to its top, marking the height Shut-off head.H₀Example: 50 mShut-off head
What it is
Head the pump develops at zero flow (discharge valve closed), read from the maker’s curve at rated speed.
Units and format
Enter a number in m: metres. The form accepts 0.000001 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 50 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
It must be above both the best-efficiency head and the static head of the system.
What this means: Best-efficiency flow
Illustration: Best-efficiency flowA pipe with liquid or gas moving through it; Best-efficiency flow is the volume that passes per unit of time.Q_BEPExample: 400 L/minBest-efficiency flow
What it is
Flow at the pump’s best efficiency point (BEP), read from the maker’s curve at rated speed.
Units and format
Enter a number in L/min: litres per minute. The form accepts 0.000001 L/min to 10000000 L/min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 400 L/min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Head at best efficiency
Illustration: Head at best efficiencyA block with a vertical dimension line from its base to its top, marking the height Head at best efficiency.H_BEPExample: 40 mHead at best efficiency
What it is
Head the pump develops at its best-efficiency flow, from the same curve. With the shut-off head it fixes the shape of the fitted pump curve.
Units and format
Enter a number in m: metres. The form accepts 0.000001 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 40 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
It must be below the shut-off head.
What this means: Best efficiency
Illustration: Best efficiencyInput on the left and useful output on the right with the loss split off; Best efficiency is output divided by input.inputuseful outputlossη_BEPExample: 75%Best efficiency
What it is
Pump efficiency at the best efficiency point, from the maker’s curve; the tool scales it down for flows away from the BEP.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 5% to 95%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 75% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Absorbed power is inversely proportional to the efficiency at the operating point.
What this means: Rated speed
Illustration: Rated speedA turning disc with a marker; Rated speed is how many full turns it makes in each minute.turns of the shaftper minuten₀Example: 1450 rpmRated speed
What it is
Speed the pump curve applies to. It is used only to turn the speed ratio for the target flow into rpm.
Units and format
Enter a number in rpm: revolutions per minute. The form accepts 0.000001 rpm to 100000 rpm. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1450 rpm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.

System

What this means: Static head (lift plus pressure difference)
Illustration: Static head (lift plus pressure difference)A block with a vertical dimension line from its base to its top, marking the height Static head (lift plus pressure difference).H_sExample: 15 mStatic head (lift plus pressure difference)
What it is
Head the system needs at zero flow: the difference in liquid level plus any pressure difference between suction and delivery vessels, expressed as head.
Units and format
Enter a number in m: metres. The form accepts 0 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 15 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Convert pressure to head of the actual liquid: head = pressure ÷ (ρ g).
What this means: Known system flow
Illustration: Known system flowA pipe with liquid or gas moving through it; Known system flow is the volume that passes per unit of time.Q_dExample: 300 L/minKnown system flow
What it is
A flow at which you know the total system head, from a pipe friction calculation or a test. It fixes the steepness of the system curve.
Units and format
Enter a number in L/min: litres per minute. The form accepts 0.000001 L/min to 10000000 L/min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 300 L/min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: System head at that flow
Illustration: System head at that flowA block with a vertical dimension line from its base to its top, marking the height System head at that flow.H_dExample: 30 mSystem head at that flow
What it is
Total system head at that known flow: static head plus pipe, fitting and valve losses.
Units and format
Enter a number in m: metres. The form accepts 0.000001 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 30 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
It must be greater than the static head.
What this means: Liquid density
Illustration: Liquid densityA cube of material: density Liquid density is its mass divided by the volume it fills.massvolumeρExample: 1000 kg/m³Liquid density
What it is
Density of the liquid being pumped at its working temperature, used for the absorbed power.
Units and format
Enter a number in kg/m³: kilograms per cubic metre. The form accepts 0.000001 kg/m³ to 20000 kg/m³. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1000 kg/m³ as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Absorbed power is proportional to density; the operating flow and head do not change.
What this means: Target flow (for the speed change)
Illustration: Target flow (for the speed change)A pipe with liquid or gas moving through it; Target flow (for the speed change) is the volume that passes per unit of time.Q_tExample: 300 L/minTarget flow (for the speed change)
What it is
The flow you want from the same system; the tool finds the pump speed that gives it using the affinity laws.
Units and format
Enter a number in L/min: litres per minute. The form accepts 0 L/min to 10000000 L/min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 300 L/min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
0 = no speed calculation.

Method and formulas

  1. Pump: H = H₀ − a Q², with a = (H₀ − H_BEP) ÷ Q_BEP²; system: H = H_s + k Q², with k = (H_d − H_s) ÷ Q_d².
  2. Operating flow Q = √[(H₀ − H_s) ÷ (a + k)].
  3. Efficiency η = η_BEP (2x − x²), x = Q ÷ Q_BEP; power = ρ g Q H ÷ η.
  4. Speed ratio s for a target flow (affinity laws): s² H₀ − a Q_t² = H_s + k Q_t².
  5. Example: the pump runs at 390.8 L/min and 40.455 m, 97.701% of its BEP flow.

Limitations

  • Quadratic fits to the pump and system curves; use the maker’s curve near the ends of the range.
  • Affinity laws hold for speed changes on the same impeller; static head limits how far speed can drop.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Predict the flow a pump will deliver on a new pipe system
  • Check that a pump runs near its best efficiency point
  • Set a variable-speed drive for a target flow

Who it is for

  • Plant engineers
  • Maintenance engineers
  • Process engineers

What you get

  • Operating flow and head
  • Efficiency, power and position against BEP
  • Speed for the target flow

Interpreting the result

  • Run between about 70% and 120% of BEP flow for long seal and bearing life.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 3021–3026. Topic reference; no source tables or recommended settings are reproduced.

Learn the Concepts Behind This Tool

These BIZOMAT Library readings explain the method this tool uses, with worked examples.

BIZOMAT tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.

Open the Pump Operating Point on the System Curve calculator