Two-Pump Arrangement Check (Parallel or Series Operating Point, Flow Gain, Each Pump’s Duty)

If I run two identical pumps in parallel or in series on this system, what flow and head do I get compared with one pump, and where does each pump run on its curve?

Operating point of two identical centrifugal pumps in parallel (heads equal, flows add) or in series (flows equal, heads add) on a system curve: the single-pump operating point (as the pump operating point tool), the combined pump curve and its intersection with the system curve, the flow gain over one pump, the flow, head, share of best-efficiency flow and efficiency of each pump, and the total power, against the flow needed.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
ArrangementchoiceParallel pumps share the flow at the same head; series pumps pass the same flow and add their heads.
Each pump at rated speed
Shut-off headmHead of each pump at zero flow.
Best-efficiency flowL/minFlow of each pump at its best efficiency.
Head at best efficiencymHead of each pump at best efficiency.
Best efficiency%Best efficiency of each pump.
System
Static headmStatic head of the system.
Known system flowL/minA known flow on the system curve.
System head at that flowmSystem head at that flow.
Liquid densitykg/m³Liquid density.
Flow neededL/minFlow the duty needs.

What each input means

Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.

What this means: Arrangement
Illustration: ArrangementThe options for Arrangement, with the one currently selected highlighted.Parallel (flows add)Series (heads add)Example: Parallel (flows add)Arrangement
What it is
How the two identical pumps are connected. In parallel they share the flow at the same head; in series the same flow passes through both and their heads add.
Units and format
Choose one of 2 options from the list: Parallel (flows add); Series (heads add).
Example
The form opens with “Parallel (flows add)” selected as a worked example. Choose the option that matches your case.
Get it right
Pick the arrangement you want to check; the tool treats the two pumps as identical, each with the curve entered below.

Each pump at rated speed

What this means: Shut-off head
Illustration: Shut-off headA block with a vertical dimension line from its base to its top, marking the height Shut-off head.H₀Example: 50 mShut-off head
What it is
The head one pump produces at zero flow, against a closed valve, at rated speed.
Units and format
Enter a number in m: metres. The form accepts 0.000001 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 50 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Read it from the pump curve at the flow axis zero point.
What this means: Best-efficiency flow
Illustration: Best-efficiency flowA pipe with liquid or gas moving through it; Best-efficiency flow is the volume that passes per unit of time.Q_bExample: 400 L/minBest-efficiency flow
What it is
The flow of one pump at its best efficiency point on the curve.
Units and format
Enter a number in L/min: litres per minute. The form accepts 0.000001 L/min to 10000000 L/min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 400 L/min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Read it from the pump curve at the efficiency peak; enter L/min.
What this means: Head at best efficiency
Illustration: Head at best efficiencyA block with a vertical dimension line from its base to its top, marking the height Head at best efficiency.H_bExample: 40 mHead at best efficiency
What it is
The head of one pump at its best efficiency flow. With the shut-off head it defines the parabolic pump curve the tool uses.
Units and format
Enter a number in m: metres. The form accepts 0.000001 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 40 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
It must be below the shut-off head.
What this means: Best efficiency
Illustration: Best efficiencyInput on the left and useful output on the right with the loss split off; Best efficiency is output divided by input.inputuseful outputlossη_bExample: 75%Best efficiency
What it is
The peak efficiency of one pump, at its best efficiency point. It is used only for the power estimate.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 5% to 95%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 75% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Type the percentage itself, read from the pump curve.

System

What this means: Static head
Illustration: Static headA block with a vertical dimension line from its base to its top, marking the height Static head.H_sExample: 15 mStatic head
What it is
The static head of the system: the height difference and pressure difference the pumps must overcome at zero flow.
Units and format
Enter a number in m: metres. The form accepts 0 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 15 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Include any pressure difference between the suction and discharge vessels, converted to head.
What this means: Known system flow
Illustration: Known system flowA pipe with liquid or gas moving through it; Known system flow is the volume that passes per unit of time.Q_dExample: 300 L/minKnown system flow
What it is
A flow at which the system head is known, used with the static head to fit the system curve.
Units and format
Enter a number in L/min: litres per minute. The form accepts 0.000001 L/min to 10000000 L/min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 300 L/min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Use a measured or calculated duty point for the existing system.
What this means: System head at that flow
Illustration: System head at that flowA block with a vertical dimension line from its base to its top, marking the height System head at that flow.H_dExample: 30 mSystem head at that flow
What it is
The total system head at the known flow, including static head and pipe friction.
Units and format
Enter a number in m: metres. The form accepts 0.000001 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 30 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
It must exceed the static head.
What this means: Liquid density
Illustration: Liquid densityA cube of material: density Liquid density is its mass divided by the volume it fills.massvolumeρExample: 1000 kg/m³Liquid density
What it is
The density of the pumped liquid, used only for the power estimate.
Units and format
Enter a number in kg/m³: kilograms per cubic metre. The form accepts 0.000001 kg/m³ to 20000 kg/m³. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1000 kg/m³ as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Use the density at the pumping temperature.
What this means: Flow needed
Illustration: Flow neededA pipe with liquid or gas moving through it; Flow needed is the volume that passes per unit of time.QExample: 420 L/minFlow needed
What it is
The flow the duty needs, compared with the combined flow of the two pumps.
Units and format
Enter a number in L/min: litres per minute. The form accepts 0 L/min to 10000000 L/min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 420 L/min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Enter L/min, the same unit as the pump and system flows.

Method and formulas

  1. Pump curve H = H₀ − a Q² through the best-efficiency point; system curve H = H_s + k Q² (as the pump operating point tool).
  2. Parallel: H₀ − a (Q ÷ 2)² = H_s + k Q². Series: 2 (H₀ − a Q²) = H_s + k Q².
  3. Each pump’s efficiency from the parabola through its best-efficiency point; power = ρ g Q H ÷ η per pump.
  4. Example: one pump gives 390.8 L/min; two give 438.18 L/min (12.122% more).

Limitations

  • Identical pumps with simple parabolic curves; real curves and unequal pumps need the makers’ data.
  • Parallel pumps need check valves; series pumps need the second casing rated for the higher pressure.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • See how much a second pump really adds
  • Choose parallel or series for a duty
  • Check each pump stays near its best efficiency

Who it is for

  • Process engineers
  • Building services engineers
  • Maintenance engineers

What you get

  • One pump alone
  • Both pumps together and the gain
  • Each pump’s flow, head and efficiency

Interpreting the result

  • On a steep (friction-dominated) system a second pump in parallel adds little flow; series suits high static head.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 3021–3026. Topic reference; no source tables or recommended settings are reproduced.