Flow Measurement by the Numbers

Chapter 1 of 10 · 10 min read

What a flowmeter measures

Volume, mass and standard volume flow and how to convert between them, mean velocity and Reynolds number, why temperature changes a litre, and a hot water recipe that came out 2.6% short.

A flowmeter’s display shows a number and a unit, and both deserve suspicion. The number may be a volume flow at the fluid’s actual temperature and pressure, a mass flow, or a volume corrected to some standard conditions, and the unit alone does not always say which. Two meters on the same pipe can disagree by several per cent while both are working perfectly, simply because they measure different quantities. Before any meter is chosen, installed or believed, it is worth being clear about what it measures and what the process actually needs.

This chapter sets out the three kinds of flow, the conversions between them, the mean velocity and Reynolds number that describe how fluid moves through a pipe, and the brewery’s five flows in those terms. It finishes with a hot water recipe, measured in litres at 80 °C and written in litres at 20 °C, that put 2.6% less water into every brew than the brewer intended.

Three kinds of flow

Volume flow is the volume passing per unit time at the conditions in the pipe, in litres per minute or cubic metres per hour. Most meters measure it, because most meters respond to the fluid’s velocity, and velocity multiplied by the pipe’s area is volume flow.

Mass flow is the mass passing per unit time, in kilograms per hour or tonnes per hour. It is what a recipe, an energy balance or a stock record usually needs, because mass does not change with temperature or pressure. Coriolis meters measure it directly; other meters infer it by multiplying volume flow by a density.

Standard volume flow is the volume the fluid would occupy at agreed reference conditions, such as 0 °C or 15 °C and 1.01325 bar. It is a disguised mass flow, used mostly for gases, because a gas’s actual volume changes dramatically with pressure and temperature. Chapter 7 returns to it for compressed air.

Figure 1Relations between the three kinds of flow
Mass flow: ṁ = ρ × Q Volume flow: Q = v̄ × A
Standard volume flow: Q_std = ṁ ÷ ρ_std = Q × (ρ ÷ ρ_std)
ṁ
mass flow, kg/s
Q
volume flow at actual conditions, m³/s
v̄
mean velocity over the pipe's cross-section, m/s
A
internal cross-sectional area of the pipe, m²
ρ is the density at the meter's conditions and ρ_std the density at the stated standard conditions. A volume flow is meaningful only with the temperature and pressure at which it applies; a standard volume flow only with the standard conditions named.

Mean velocity and the pipe’s bore

Fluid in a pipe does not move at one speed. It is slowest at the wall, where it is held by friction, and fastest near the centre. The mean velocity, v̄, is the volume flow divided by the internal area, and it is the single number that describes how hard the fluid is moving. The internal bore matters, not the nominal size: a DN50 stainless tube with a 1.5 mm wall has a bore of 47.8 mm, while DN50 schedule 40 carbon steel pipe has a bore of 52.5 mm, and the areas differ by 21%.

The pipe flow velocity tool gives the mean velocity from a flow in litres per minute and a bore in millimetres. The brewery’s wort line carries 12 m³/h, or 200 L/min, through a 47.8 mm bore: the tool gives a flow area of 1,794.5 mm² and a mean velocity of 1.858 m/s.

Reynolds number

Whether the flow is smooth and layered or turbulent and mixed depends on the ratio of the fluid’s inertia to its viscosity, expressed as the Reynolds number. It decides the shape of the velocity profile, which every meter depends on, as Chapter 2 explains.

Figure 2Reynolds number in a full pipe
Re = v̄ × D ÷ ν
Re
Reynolds number, dimensionless
ν
kinematic viscosity, m²/s; 1.14 × 10⁻⁶ for water at 15 °C
D is the internal bore and ν the kinematic viscosity, the dynamic viscosity divided by the density. In pipes, flow is laminar below about 2,000 and fully turbulent above about 4,000; most industrial liquid and gas flows are turbulent.

The liquid pipe velocity and Reynolds number tool calculates both together. For the mains water through FT-101, 30 m³/h, or 500 L/min, in an 80.0 mm bore with water at 15 °C and a kinematic viscosity of 1.14 mm²/s, it gives a mean velocity of 1.658 m/s and a Reynolds number of 116,000, well into turbulent flow.

Figure 3The brewery's five flows at their normal rates
MeterBoreNormal flowMean velocityReynolds numberMeter measures
FT-101 mains water, 15 °C80.0 mm30 m³/h1.66 m/s116,000volume at line conditions
FT-201 wort, 18 °C, SG 1.04847.8 mm12 m³/h1.86 m/sabout 55,000mass, and density
FT-301 hot liquor, 80 °C62.7 mm15 m³/h1.35 m/sabout 230,000volume at 80 °C, from a pressure difference
FT-401 compressed air, 7 bar gauge52.5 mmabout 4 m³/min free airsee Chapter 7highvolume at line conditions, corrected to standard
FT-501 glycol, 30% by mass, about −2 °C102.3 mm nominalsee Chapter 6—lower, owing to viscosityvolume at line conditions
This is an illustration. Kinematic viscosities: water 1.14 mm²/s at 15 °C and 0.365 mm²/s at 80 °C; wort about 1.6 mm²/s. Glycol and air are worked in Chapters 6 and 7.

Density and temperature

Converting between volume and mass needs the density at the meter’s conditions, and for liquids the important variable is temperature. Water’s density is 998.2 kg/m³ at 20 °C and 971.8 kg/m³ at 80 °C, 2.6% less. A litre of water at 80 °C contains 2.6% less water than a litre at 20 °C.

Wort is denser than water, because it carries dissolved sugars. Brewers express its strength as specific gravity, the ratio of its density to water’s, or in degrees Plato, the mass percentage of extract. The density and specific gravity converter converts a specific gravity of 1.048 to 1,048.0 kg/m³, taking water at its maximum density as the reference. The wort line’s 12 m³/h is therefore 12 × 1,048 = 12,576 kg/h, the figure the brewer’s extract and yield calculations need.

Brewers often convert specific gravity to degrees Plato with the approximation °P ≈ 259 − 259 ÷ SG, which gives 259 − 259 ÷ 1.048 = 11.9 °P for the brewery’s wort, close to the 12 °P its recipe targets. The approximation is good enough for the brewhouse; the extract tables of the brewing industry, or the Coriolis meter’s own conversion, should be used where a gravity is reported. Either way, the gravity is a property measured at a stated temperature, usually 20 °C, and a hot wort’s density must be corrected before it is converted.

Liquids are slightly compressible

For liquids, pressure barely matters. Water’s volume falls by about 0.05% for every 10 bar, so a line pressure of a few bar changes a volume reading by a few hundredths of a per cent, less than any process meter’s uncertainty. Gases are a different matter, because their volume is inversely proportional to absolute pressure, and Chapter 7 deals with them.

Full pipes, one phase

Every meter in this book assumes that the pipe is full of a single fluid. A liquid line that runs partly empty, at a high point or downstream of a valve that drains it, presents the meter with a smaller area of moving liquid than it assumes, and velocity-based meters read high or erratically. Bubbles in a liquid, or droplets in a gas, change the density, the speed of sound and the electrical behaviour that different meters rely on, each in its own way. At the brewery the commonest culprit is carbon dioxide coming out of solution in fermenting or warm beer, and Chapter 5 meets it in the wort line. Installation, which Chapter 2 covers, is largely about guaranteeing full pipes and clean, single-phase flow at the meter.

Process meters and trade meters

The brewery’s water is billed by the water authority from its own meter at the property boundary. That meter, like any meter used to determine a price, is a trade meter. In Australia, trade measuring instruments must be of a pattern approved by the National Measurement Institute and must be verified, and their use is governed by trade measurement law. The brewery’s own meters, FT-101 to FT-501, are process meters: they are used to run and improve the brewery, not to bill anyone, and no legal approval applies to them.

The distinction matters in two ways. A process meter that disagrees with the trade meter does not overturn the bill, though a persistent disagreement is worth raising with the authority, which can test its meter. And a process meter used informally for trade, such as to charge a tenant for water, may need to meet trade requirements. The brewery uses FT-101 to watch its own consumption and to check the authority’s meter, and the two have agreed within 1% over each billing period, a useful check on both.

Units and their traps

Flow units mix volume or mass with time, and both halves cause mistakes. Litres per minute and cubic metres per hour differ by a factor of 16.67; kilograms per hour and tonnes per hour by a thousand; and imported equipment may display United States gallons per minute, about 3.785 L/min each, or imperial gallons, about 4.546 L/min. A totaliser’s units must match its flow’s: a flow in m³/h fed to a totaliser that expects L/min gives a total wrong by a factor of 16.67. Most of these errors are caught by the velocity check of this chapter’s checklist, because they put a reasonable flow at an unreasonable velocity.

The range of flows, not just the normal one

A meter is chosen for a range, not for one flow. FT-101 sees 30 m³/h when the brewhouse is filling its hot liquor tank, a few cubic metres an hour during cleaning, and as little as 0.5 m³/h overnight from toilets, a leaking float valve or a cooling tower’s make-up. At 0.5 m³/h the mean velocity in its 80 mm bore is only 0.028 m/s, and the ratio of the highest to the lowest flow, the turndown it must cover, is 60 to 1. Many meters lose accuracy at very low velocities, and the brewery’s night flow, which is where leaks show up, is exactly the reading it most wants to trust. Chapter 8 shows how a meter’s accuracy at the bottom of its range depends on whether its uncertainty is stated as a percentage of the reading or of the full scale, and Chapter 10 how the range shapes the choice of meter.

What the process needs

Choosing which quantity to measure starts with the question the reading must answer.

Figure 4Which kind of flow the brewery needs at each point
Water bills and the site water balanceVolume, at the meter's own conditionsFT-101 reads cold mains water; the water authority bills by volume
Extract, yield and batch size of wortMass, and density for gravityFT-201's Coriolis meter gives both
Hot liquor for each brewMass, or volume at a stated temperatureFT-301 reads volume at 80 °C; the recipe must say which
Compressed air use and leaksStandard volume, as free airFT-401 must be corrected for pressure and temperature
Glycol circulation for cooling capacityVolume, with temperatures, for heat flowFT-501 audits the loop occasionally
This is an illustration of the reasoning.

The mistake: hot liquor by the litre

The brewery’s recipes give the volume of hot liquor for each brew in litres: 1,900 L for the house pale ale. The brewer had always taken those litres to mean water at 20 °C, as the recipe software assumed when it calculated the mash’s thickness and the expected gravity. FT-301, measuring the hot liquor at 80 °C, delivered 1,900 L at 80 °C.

Over several months the brewer noticed that the pale ale’s original gravity was running consistently a little above the recipe’s prediction, and that the mash seemed thicker than it should. The quality manager traced the difference to the hot liquor.

Figure 5Finding the missing water
  1. Recipe1,900 L of hot liquor, assumed by the software to be at 20 °C, 1,897 kg
  2. Delivered1,900 L measured at 80 °C by FT-301
  3. Mass delivered1,900 × 0.9718 = 1,846 kg, 50 kg or 2.6% less than the recipe assumed
  4. Effectthicker mash and slightly higher gravity than predicted on every brew
  5. Fixrecipe quantities converted to mass; FT-301's volume converted to mass at the measured temperature by the control system
This is an illustration. 1,900 L at 80 °C holds 1,846 kg; 1,900 L at 20 °C would hold 1,897 kg.

The 1,900 L delivered at 80 °C contained 1,900 × 0.9718 = 1,846 kg of water, 50 kg, or 2.6%, less than the 1,897 kg the recipe software had assumed. The mash was correspondingly thicker and the gravity a little higher. The fix was to express recipe quantities in kilograms and to have the control system multiply FT-301’s volume by the density at its measured temperature. The difference was within the brewer’s normal adjustments, which is why it went unnoticed for so long, but it was a systematic error on every brew, and it made the recipe software’s predictions wrong in a consistent direction.

Checking a flow reading

A few quick checks catch most misunderstandings about what a reading means.

Figure 6Before trusting a flow reading
  • Avoid: Volume, mass or standard volumethe meter's display unit and configuration say which
  • Avoid: Conditions of a volumethe temperature and pressure at which it applies
  • Ask: Conditions the user assumesa recipe, bill or report in another temperature's litres
  • Avoid: Standard conditions named0 °C, 15 °C or 20 °C, and the reference pressure
  • Avoid: Bore, not nominal sizefor any calculation of velocity from flow
  • Avoid: Velocity reasonableabout 0.5 to 3 m/s for liquids in process lines
The open item is this chapter's mistake: a volume without its temperature is half a number.

The last check is a useful sanity test. Liquid velocities in process pipes are usually between about 0.5 and 3 m/s. A calculated velocity far outside that range usually means a wrong bore, a wrong unit or a meter in the wrong size of pipe.

Exercise: wort by mass and volume

A brew of 2,500 L of wort at 18 °C and a specific gravity of 1.048 is transferred through FT-201 in 12.5 minutes. Calculate the volume flow in m³/h, the mean velocity in the 47.8 mm bore, the mass transferred and the mass flow. Then calculate the volume the same mass of wort would occupy at 98 °C, at the end of the boil, taking its density there as 1,010 kg/m³, and say which number the brewer should use to judge the brew’s size.

Answer

Given: V = 2.500 m³; t = 12.5 min; SG 1.048, ρ = 1,048 kg/m³ at 18 °C; ρ = 1,010 kg/m³ at 98 °C; bore 47.8 mm.

Assumptions: steady flow; the density uniform through the transfer.

Method: Q = V ÷ t; v̄ = Q ÷ A; m = ρ V; ṁ = m ÷ t; V_hot = m ÷ ρ_hot.

Volume flow: 2.500 ÷ (12.5 ÷ 60) = 12.0 m³/h.

Mean velocity: A = π × 0.0478² ÷ 4 = 1.7945 × 10⁻³ m²; v̄ = (12.0 ÷ 3,600) ÷ 1.7945 × 10⁻³ = 1.858 m/s.

Mass: 1,048 × 2.500 = 2,620 kg. Mass flow: 2,620 ÷ 12.5 = 209.6 kg/min, or 12,576 kg/h.

Volume at 98 °C: 2,620 ÷ 1,010 = 2.594 m³, about 2,594 L.

Which to use: the mass, 2,620 kg, which does not change with temperature. The same wort is 2,594 L at the end of the boil and 2,500 L cooled, a difference of 3.8%, enough to make a brew look larger or smaller depending on when it was measured. Volumes can be reported, but only with their temperature. The brewery now records every transfer in kilograms, with the volume and temperature alongside for the brewers who think in litres.

Verification: the pipe flow velocity tool, with 200 L/min and a 47.8 mm bore, gives 1.858 m/s, and the ratio of the two volumes equals the inverse ratio of the densities: 1,048 ÷ 1,010 = 1.038.