Compressed-Air System Sizing

How big a compressor, receiver and main pipe does this plant need, and what do the leaks cost?

Sizing a compressed-air system from the average demand: compressor free-air delivery with leakage and growth allowances, theoretical compression power with an overall efficiency (the same method as the compressor power tool), receiver volume to cover a peak deficit within the pressure band, the main pipe bore that keeps the pressure drop within a limit (Darcy–Weisbach, as the air line tool), and the annual energy cost of leakage.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Demand
Average demand of the usersm³/min FADAverage free-air demand of all users together (after diversity).
Leakage allowance%Air lost to leaks, as a share of demand (often 20–30% in unsurveyed plants).
Future growth allowance%Allowance for future users.
Peak demand above compressor outputm³/minShort-term demand above what the compressor supplies.
Duration of the peakminHow long that peak lasts.
Pressure
Working pressurebar gPressure needed at the users.
Receiver upper pressurebar gPressure at which the compressor unloads.
Receiver lower pressurebar gLowest acceptable receiver pressure.
Main pipe
Main pipe length (incl. fitting allowance)mLength of the main pipe run, plus an allowance for fittings.
Allowable pressure dropbarLargest pressure drop you accept along the main.
Air temperature°CTemperature of the air in the main.
Pipe roughnessmmPipe roughness.
Energy
Compressor overall efficiency%Overall efficiency relating theoretical adiabatic power to shaft power.
Running hours per yearhHours the system is pressurised each year.
Electricity price$/kWhCost of electricity.

What each input means

Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.

Demand

What this means: Average demand of the users
Illustration: Average demand of the usersA pipe with liquid or gas moving through it; Average demand of the users is the volume that passes per unit of time.QExample: 5 m³/min FADAverage demand of the users
What it is
Average free-air demand of all the air users together, after allowing for the fact that they do not all run at once.
Units and format
Enter a number in m³/min FAD: m³/min FAD. The form accepts 0.000001 m³/min FAD to 10000 m³/min FAD. Required: the tool does not calculate until every input is valid.
Example
The form opens with 5 m³/min FAD as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Compressor capacity, power and pipe size rise with demand.
Get it right
Use free air delivery (FAD): volume at intake conditions, not compressed volume.
What this means: Leakage allowance
Illustration: Leakage allowanceA bar of 100 parts with the share marked; Leakage allowance is that share out of 100. The bar follows the value you type.0 %100 %Example: 15%Leakage allowance
What it is
Air lost through leaks, as a percentage of the users’ demand, added on top of the demand.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 0% to 100%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 15% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Raises compressor capacity and the annual cost of leaks.
Get it right
A leak survey gives the real figure; type a percentage.
What this means: Future growth allowance
Illustration: Future growth allowanceA bar of 100 parts with the share marked; Future growth allowance is that share out of 100. The bar follows the value you type.0 %100 %Example: 20%Future growth allowance
What it is
Extra capacity, as a percentage, kept for users you expect to add in future.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 0% to 200%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 20% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Compressor capacity, power and pipe size rise with it.
Get it right
It is applied after leakage, so the two allowances compound.
What this means: Peak demand above compressor output
Illustration: Peak demand above compressor outputA pipe with liquid or gas moving through it; Peak demand above compressor output is the volume that passes per unit of time.QExample: 2 m³/minPeak demand above compressor output
What it is
The free-air flow by which a short peak in demand exceeds what the compressor delivers. The receiver must supply this difference.
Units and format
Enter a number in m³/min: cubic metres per minute. The form accepts 0 m³/min to 10000 m³/min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 2 m³/min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Receiver volume rises in proportion.
Get it right
Enter it as free air, like the demand, not as compressed volume.
What this means: Duration of the peak
Illustration: Duration of the peakA timeline from a start mark to an end mark; Duration of the peak is the time between them.startendtExample: 1 minDuration of the peak
What it is
How long the peak demand above compressor output lasts.
Units and format
Enter a number in min: minutes. The form accepts 0 min to 600 min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1 min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Receiver volume rises in proportion.
Get it right
Enter minutes, not seconds.

Pressure

What this means: Working pressure
Illustration: Working pressureA pressure gauge whose needle moves with Working pressure; the needle follows the value you type.pExample: 7 bar gWorking pressure
What it is
Gauge pressure the users need at the end of the main. It sets the air density for the pipe sizing and is compared with the receiver lower pressure.
Units and format
Enter a number in bar g: bar g. The form accepts 0.000001 bar g to 50 bar g. Required: the tool does not calculate until every input is valid.
Example
The form opens with 7 bar g as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Gauge pressure (bar g) is above atmospheric; do not add atmospheric pressure.
What this means: Receiver upper pressure
Illustration: Receiver upper pressureA pressure gauge whose needle moves with Receiver upper pressure; the needle follows the value you type.p₁Example: 8 bar gReceiver upper pressure
What it is
Gauge pressure at which the compressor unloads or stops, the top of the receiver’s pressure band. Compressor power is calculated to this pressure.
Units and format
Enter a number in bar g: bar g. The form accepts 0.000001 bar g to 50 bar g. Required: the tool does not calculate until every input is valid.
Example
The form opens with 8 bar g as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
A higher upper pressure raises power but widens the band, reducing receiver volume.
Get it right
Gauge pressure; it must be higher than the lower receiver pressure.
What this means: Receiver lower pressure
Illustration: Receiver lower pressureA pressure gauge whose needle moves with Receiver lower pressure; the needle follows the value you type.p₂Example: 6.5 bar gReceiver lower pressure
What it is
Lowest gauge pressure the receiver may fall to during a peak, the bottom of its pressure band.
Units and format
Enter a number in bar g: bar g. The form accepts 0.000001 bar g to 50 bar g. Required: the tool does not calculate until every input is valid.
Example
The form opens with 6.5 bar g as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
A lower limit widens the band and reduces receiver volume.
Get it right
Keep it at or above the working pressure, or users will be starved during peaks.

Main pipe

What this means: Main pipe length (incl. fitting allowance)
Illustration: Main pipe length (incl. fitting allowance)A bar with a dimension line and arrows from one end to the other, marking the length Main pipe length (incl. fitting allowance).LExample: 100 mMain pipe length (incl. fitting allowance)
What it is
Length of the main pipe run from the compressor room to the furthest user, plus an equivalent length allowance for bends, tees and valves.
Units and format
Enter a number in m: metres. The form accepts 0.000001 m to 100000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 100 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
A longer main needs a larger bore for the same pressure drop.
Get it right
Add the equivalent length of fittings to the straight length.
What this means: Allowable pressure drop
Illustration: Allowable pressure dropA pressure gauge whose needle moves with Allowable pressure drop; the needle follows the value you type.ΔpExample: 0.1 barAllowable pressure drop
What it is
Largest pressure loss you accept along the main between compressor and users. The tool finds the smallest bore that meets it.
Units and format
Enter a number in bar: bar (1 bar = 100 kPa). The form accepts 0.000001 bar to 5 bar. Required: the tool does not calculate until every input is valid.
Example
The form opens with 0.1 bar as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
A tighter limit needs a larger pipe bore.
Get it right
This is a pressure difference, so gauge or absolute does not matter.
What this means: Air temperature
Illustration: Air temperatureA thermometer whose level rises with Air temperature; the level follows the value you type.TExample: 25 °CAir temperature
What it is
Temperature of the compressed air flowing in the main, used for its density and actual flow volume.
Units and format
Enter a number in °C: degrees Celsius. The form accepts -20 °C to 100 °C. Required: the tool does not calculate until every input is valid.
Example
The form opens with 25 °C as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Use the air temperature after the aftercooler, not the compressor discharge temperature.
What this means: Pipe roughness
Illustration: Pipe roughnessA magnified surface profile with peaks and valleys around a mean line; the average deviation from that line is Pipe roughness.mean lineεExample: 0.045 mmPipe roughness
What it is
Absolute roughness of the main pipe’s inner wall, used in the friction factor for the pressure-drop calculation.
Units and format
Enter a number in mm: millimetres. The form accepts 0 mm to 5 mm. Required: the tool does not calculate until every input is valid.
Example
The form opens with 0.045 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Take it from pipe data for the pipe material; corroded steel is rougher than new.

Energy

What this means: Compressor overall efficiency
Illustration: Compressor overall efficiencyInput on the left and useful output on the right with the loss split off; Compressor overall efficiency is output divided by input.inputuseful outputlossηExample: 75%Compressor overall efficiency
What it is
Overall efficiency relating the theoretical single-stage adiabatic power to the actual shaft power of the compressor.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 20% to 100%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 75% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Shaft power and leak cost rise as efficiency falls.
Get it right
Compressor makers publish specific power; work back from it if you can. Type the percentage.
What this means: Running hours per year
Illustration: Running hours per yearA timeline from a start mark to an end mark; Running hours per year is the time between them.startendhExample: 4000 hRunning hours per year
What it is
Hours per year the system is pressurised, during which leaks waste air whether or not production is running.
Units and format
Enter a number in h: hours. The form accepts 0.000001 h to 8760 h. Required: the tool does not calculate until every input is valid.
Example
The form opens with 4000 h as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Annual leak cost rises in proportion.
Get it right
Include nights and weekends if the system stays pressurised.
What this means: Electricity price
Illustration: Electricity priceA price tag on one unit of measure; Electricity price is the cost for each unit (per hour, per kilogram and so on).$cost foreach unitExample: $0.25/kWhElectricity price
What it is
Price paid for one kilowatt-hour of electricity, used for the annual cost of leaks.
Units and format
Enter a number in $/kWh: money per kilowatt-hour. The form accepts $0/kWh to $10/kWh. Required: the tool does not calculate until every input is valid.
Example
The form opens with $0.25/kWh as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Annual leak cost rises in proportion.
Get it right
Use the average delivered price including network charges, from your electricity bills.

Method and formulas

  1. Compressor FAD = Q × (1 + leak) × (1 + growth).
  2. Power = single-stage adiabatic k = 1.4 from 1.013 bar to (p₁ + 1.013) bar ÷ efficiency.
  3. Receiver V = deficit × time × 1.013 ÷ (p₁ − p₂).
  4. Main bore found so the Darcy–Weisbach drop with Colebrook friction at working pressure equals the limit.
  5. Leak cost = leak flow × specific power × hours × price.
  6. Example: 5 m³/min of demand needs a 6.9 m³/min compressor of about 47.156 kW, a 1,351 L receiver and a 50.922 mm main.

Limitations

  • Single-stage power estimate; real compressors publish their own specific power.
  • Pipe bore is the minimum internal bore; choose the next larger standard pipe.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Plan a compressor, receiver and ring main for a workshop
  • Show the energy cost of leaks to justify a leak survey
  • Check a plant after adding air users

Who it is for

  • Plant engineers
  • Compressed-air engineers
  • Maintenance managers

What you get

  • Compressor capacity and power
  • Receiver volume
  • Main pipe bore and leak cost

Interpreting the result

  • Fixing leaks is usually the cheapest capacity increase available.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 3030–3037, 3421–3425. Topic reference; no source tables or recommended settings are reproduced.

Learn the Concepts Behind This Tool

These BIZOMAT Library readings explain the method this tool uses, with worked examples.

BIZOMAT tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.

Open the Compressed-Air System Sizing calculator