Machine Coolant System Sizing

How much coolant flow, tank volume and pump power does this machine need?

Sizing of a machine-tool coolant system: the flow to carry the cutting heat away at an allowed temperature rise (as the coolant heat-flow tool), the flow the nozzles need for the jet velocity, the governing flow, tank volume for the chosen turnover time, and pump shaft power for the head and efficiency (as the pump power tool).

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Cutting powerkWCutting power at the spindle during heavy cuts.
Share of cutting heat into the coolant%Share of the heat carried by the coolant (most goes into chips and coolant).
Allowed coolant temperature riseKTemperature rise of the coolant you accept per pass.
Coolant specific heatkJ/kg·KSpecific heat of the coolant (about 4.0 for water-based emulsions).
Coolant densitykg/m³Coolant density.
Number of nozzlesNumber of nozzles delivering coolant.
Nozzle boremmBore of each nozzle.
Jet velocitym/sJet velocity wanted at the nozzle (higher for chip flushing).
Tank turnover timeminMinutes of flow the tank holds (5–10 settles chips and releases air).
Pump headmTotal head the pump must deliver (nozzle pressure plus losses).
Pump efficiency%Pump efficiency.

What each input means

Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.

What this means: Cutting power
Illustration: Cutting powerA motor driving a shaft; Cutting power is the rate at which it does work, energy per second.P_cExample: 10 kWCutting power
What it is
Power used at the cutting edge during the heaviest cuts, from a cutting power calculation or the measured spindle load.
Units and format
Enter a number in kW: kilowatts. The form accepts 0.000001 kW to 10000 kW. Required: the tool does not calculate until every input is valid.
Example
The form opens with 10 kW as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
The flow needed for heat rises in proportion.
What this means: Share of cutting heat into the coolant
Illustration: Share of cutting heat into the coolantA bar of 100 parts with the share marked; Share of cutting heat into the coolant is that share out of 100. The bar follows the value you type.0 %100 %Example: 70%Share of cutting heat into the coolant
What it is
Share of the cutting heat that ends up in the coolant rather than in the chips, the part and the air.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 0% to 100%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 70% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
The flow needed for heat rises in proportion.
Get it right
Type the percentage, not a fraction.
What this means: Allowed coolant temperature rise
Illustration: Allowed coolant temperature riseTwo thermometers at different levels with the difference between them marked; Allowed coolant temperature rise is that temperature difference.ΔTExample: 5 KAllowed coolant temperature rise
What it is
How much the coolant may warm up in one pass through the cutting zone before it returns to the tank.
Units and format
Enter a number in K: kelvin (a difference of 1 K equals 1 °C). The form accepts 0.000001 K to 50 K. Required: the tool does not calculate until every input is valid.
Example
The form opens with 5 K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Halving the allowed rise doubles the flow needed for heat.
What this means: Coolant specific heat
Illustration: Coolant specific heatHeat flowing from a hot side to a cold side through a wall or into a material; Coolant specific heat sets how much heat moves or is stored.hotcoldc_pExample: 4 kJ/kg·KCoolant specific heat
What it is
Heat needed to warm one kilogram of the coolant by one kelvin, from the coolant supplier’s data.
Units and format
Enter a number in kJ/kg·K: kilojoules per kilogram per kelvin. The form accepts 0.000001 kJ/kg·K to 6 kJ/kg·K. Required: the tool does not calculate until every input is valid.
Example
The form opens with 4 kJ/kg·K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Check the unit: kJ/kg·K, not J/kg·K.
What this means: Coolant density
Illustration: Coolant densityA cube of material: density Coolant density is its mass divided by the volume it fills.massvolumeρExample: 1000 kg/m³Coolant density
What it is
Mass of one cubic metre of the coolant, used for both the heat flow and the pump power.
Units and format
Enter a number in kg/m³: kilograms per cubic metre. The form accepts 0.000001 kg/m³ to 2000 kg/m³. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1000 kg/m³ as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Number of nozzles
Illustration: Number of nozzlesA row of identical items being counted; Number of nozzles is how many there are.nExample: 4Number of nozzles
What it is
Number of nozzles delivering coolant at the same time, which with bore and jet speed sets the nozzle flow.
Units and format
Enter a plain number with no unit. The form accepts 0 to 200. Use a whole number. Required: the tool does not calculate until every input is valid.
Example
The form opens with 4 as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
0 = no nozzle requirement: the flow is sized on heat alone.
What this means: Nozzle bore
Illustration: Nozzle boreA circle with a line straight through its centre from edge to edge, marking the diameter Nozzle bore.Ømeasured acrossthe centreExample: 3 mmNozzle bore
What it is
Bore of the outlet of each nozzle, where the jet leaves.
Units and format
Enter a number in mm: millimetres. The form accepts 0.000001 mm to 100 mm. Required: the tool does not calculate until every input is valid.
Example
The form opens with 3 mm as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Nozzle flow rises with the square of the bore.
What this means: Jet velocity
Illustration: Jet velocityA marker moving along a track; Jet velocity is the distance it covers per unit of time.vdistance ÷ timeExample: 10 m/sJet velocity
What it is
Speed of the coolant jet as it leaves each nozzle; faster jets flush chips better but need more flow and pressure.
Units and format
Enter a number in m/s: metres per second. The form accepts 0.000001 m/s to 200 m/s. Required: the tool does not calculate until every input is valid.
Example
The form opens with 10 m/s as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Nozzle flow rises in proportion to jet speed.
What this means: Tank turnover time
Illustration: Tank turnover timeA timeline from a start mark to an end mark; Tank turnover time is the time between them.startendtExample: 5 minTank turnover time
What it is
How many minutes of design flow the tank holds, giving time for chips to settle and air to escape before the coolant is pumped again.
Units and format
Enter a number in min: minutes. The form accepts 0.000001 min to 1000 min. Required: the tool does not calculate until every input is valid.
Example
The form opens with 5 min as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Tank volume = design flow × turnover time.
What this means: Pump head
Illustration: Pump headA block with a vertical dimension line from its base to its top, marking the height Pump head.HExample: 20 mPump head
What it is
Total head the pump must deliver at the design flow: nozzle pressure expressed as head, plus pipe, filter and lift losses.
Units and format
Enter a number in m: metres. The form accepts 0.000001 m to 5000 m. Required: the tool does not calculate until every input is valid.
Example
The form opens with 20 m as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Pump power rises in proportion to head.
Get it right
Head in metres of coolant, not bar: convert pressure with head = pressure ÷ (ρ g).
What this means: Pump efficiency
Illustration: Pump efficiencyInput on the left and useful output on the right with the loss split off; Pump efficiency is output divided by input.inputuseful outputlossηExample: 60%Pump efficiency
What it is
Efficiency of the coolant pump at the duty point, from the pump maker’s curve.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 5% to 100%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 60% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Pump shaft power is inversely proportional to efficiency.

Method and formulas

  1. Flow for heat Q = heat ÷ (ρ c_p ΔT).
  2. Nozzle flow = number × area × jet velocity; design flow = the larger.
  3. Tank volume = design flow × turnover time.
  4. Pump shaft power = ρ g Q H ÷ η.
  5. Example: 10 kW of cutting needs 21 L/min, a 105 L tank and a 0.11441 kW pump.

Limitations

  • Average heat; through-spindle and high-pressure systems need their own pump curves.
  • Tank size also depends on chip settling and filtration.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Specify a coolant pump and tank for a machine
  • Check whether a coolant system keeps temperature stable
  • Size a central coolant supply for several machines

Who it is for

  • Machinists
  • Manufacturing engineers
  • Tooling engineers

What you get

  • Flow for heat and for nozzles
  • Tank volume
  • Pump power

Interpreting the result

  • If nozzle flow governs, fewer, better-aimed nozzles save pump power.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 1112–1121, 1183–1190. Topic reference; no source tables or recommended settings are reproduced.

BIZOMAT tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.