Gearbox Oil Temperature and Grade Check (Heat Balance, Viscosity Hot)

At what temperature will my gearbox oil settle, does it need a cooler, and is the oil grade still thick enough at that temperature?

Check of a gearbox’s steady oil temperature and its lubricant: heat generated from the power and efficiency, the equilibrium oil temperature from the housing’s dissipation, the thermal power limit, cooler duty and oil flow if needed (as the gearbox heat balance tool), and the oil’s viscosity at the running temperature (the equilibrium temperature, or the limit if a cooler holds it there) from its viscosity at 40 °C and 100 °C (as the oil viscosity–temperature tool), against the least viscosity the gears need.

Open the calculatorRuns in your browser. No account needed.

How this tool works

Inputs, units and where to find them

InputUnitTypical source
Input powerkWPower going into the gearbox.
Gearbox efficiency%Overall efficiency of the gearbox.
Heat-dissipating surface aream²Outside surface area of the housing that sheds heat.
Heat transfer coefficientW/m²·KCombined convection and radiation coefficient of the housing (higher with a shaft fan).
Ambient temperature°CAir temperature around the gearbox.
Maximum oil temperature°CHighest oil temperature you allow.
Oil temperature drop across a coolerKTemperature drop of oil through a cooler, if one is needed.
Oil specific heatkJ/kg·KSpecific heat of the oil.
Oil densitykg/m³Density of the oil.
Oil grade
Viscosity at 40 °CcStKinematic viscosity of the oil at 40 °C (from the data sheet).
Viscosity at 100 °CcStKinematic viscosity at 100 °C.
Least viscosity the gears need at running temperaturecStLeast viscosity the gear maker requires at the running temperature.

What each input means

Open an input to see what it is, its units, the worked example and the common mistakes, with a small diagram.

What this means: Input power
Illustration: Input powerA motor driving a shaft; Input power is the rate at which it does work, energy per second.PExample: 15 kWInput power
What it is
The mechanical power entering the gearbox input shaft under the steady running load being checked.
Units and format
Enter a number in kW: kilowatts. The form accepts 0.000001 kW to 100000 kW. Required: the tool does not calculate until every input is valid.
Example
The form opens with 15 kW as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Heat generated is proportional to input power.
Get it right
Use the actual running power, not the motor nameplate, if the drive runs below rating; heat follows real power.
What this means: Gearbox efficiency
Illustration: Gearbox efficiencyInput on the left and useful output on the right with the loss split off; Gearbox efficiency is output divided by input.inputuseful outputlossηExample: 92%Gearbox efficiency
What it is
The share of input power that leaves through the output shaft; the remainder becomes heat in the oil and housing.
Units and format
Enter a number in %: percent: the number is read as a percentage, so type 8 for 8 %. The form accepts 10% to 99.9%. Required: the tool does not calculate until every input is valid.
Example
The form opens with 92% as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
Higher efficiency lowers the heat generated and the oil temperature.
Get it right
Type a percentage, not a fraction; small errors matter because the heat follows 100 minus the efficiency.
What this means: Heat-dissipating surface area
Illustration: Heat-dissipating surface areaA shaded shape whose enclosed surface is the area Heat-dissipating surface area.AenclosedsurfaceExample: 2 m²Heat-dissipating surface area
What it is
The external surface area of the gearbox housing exposed to air that sheds heat, from the maker’s data or measured from the housing.
Units and format
Enter a number in m²: square metres. The form accepts 0.000001 m² to 10000 m². Required: the tool does not calculate until every input is valid.
Example
The form opens with 2 m² as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
The oil temperature rise above ambient falls in inverse proportion to the area.
What this means: Heat transfer coefficient
Illustration: Heat transfer coefficientHeat flowing from a hot side to a cold side through a wall or into a material; Heat transfer coefficient sets how much heat moves or is stored.hotcoldhExample: 15 W/m²·KHeat transfer coefficient
What it is
The combined rate at which the housing surface loses heat to the air by convection and radiation, per square metre and per kelvin of temperature difference.
Units and format
Enter a number in W/m²·K: watts per square metre per kelvin. The form accepts 0.000001 W/m²·K to 500 W/m²·K. Required: the tool does not calculate until every input is valid.
Example
The form opens with 15 W/m²·K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Effect on the result
The oil temperature rise above ambient falls in inverse proportion to this coefficient.
Get it right
Take it from the gearbox maker or a heat transfer reference for your mounting and air flow; a shaft fan changes it greatly.
What this means: Ambient temperature
Illustration: Ambient temperatureA thermometer whose level rises with Ambient temperature; the level follows the value you type.TₐExample: 30 °CAmbient temperature
What it is
The air temperature around the gearbox in service, including heat from nearby equipment or sun.
Units and format
Enter a number in °C: degrees Celsius. The form accepts -40 °C to 80 °C. Required: the tool does not calculate until every input is valid.
Example
The form opens with 30 °C as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Maximum oil temperature
Illustration: Maximum oil temperatureA thermometer whose level rises with Maximum oil temperature; the level follows the value you type.TmaxExample: 80 °CMaximum oil temperature
What it is
The highest steady oil temperature you allow; above it the tool sizes a cooler and runs the viscosity check at this temperature.
Units and format
Enter a number in °C: degrees Celsius. The form accepts 20 °C to 150 °C. Required: the tool does not calculate until every input is valid.
Example
The form opens with 80 °C as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
What this means: Oil temperature drop across a cooler
Illustration: Oil temperature drop across a coolerTwo thermometers at different levels with the difference between them marked; Oil temperature drop across a cooler is that temperature difference.ΔTExample: 5 KOil temperature drop across a cooler
What it is
The temperature drop of the oil as it passes through an oil cooler, used only to size the oil flow when a cooler is needed.
Units and format
Enter a number in K: kelvin (a difference of 1 K equals 1 °C). The form accepts 0.000001 K to 50 K. Required: the tool does not calculate until every input is valid.
Example
The form opens with 5 K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
It affects only the cooler oil flow; the oil temperature and viscosity results do not depend on it.
What this means: Oil specific heat
Illustration: Oil specific heatHeat flowing from a hot side to a cold side through a wall or into a material; Oil specific heat sets how much heat moves or is stored.hotcoldcₚExample: 1.9 kJ/kg·KOil specific heat
What it is
The specific heat capacity of the oil, from the oil data sheet; used only to work out the oil flow through a cooler.
Units and format
Enter a number in kJ/kg·K: kilojoules per kilogram per kelvin. The form accepts 0.000001 kJ/kg·K to 5 kJ/kg·K. Required: the tool does not calculate until every input is valid.
Example
The form opens with 1.9 kJ/kg·K as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Enter kJ/kg·K, not J/kg·K: divide a value in joules by 1000.
What this means: Oil density
Illustration: Oil densityA cube of material: density Oil density is its mass divided by the volume it fills.massvolumeρExample: 870 kg/m³Oil density
What it is
The density of the oil, from the oil data sheet; used only to convert the cooler heat duty into an oil flow rate.
Units and format
Enter a number in kg/m³: kilograms per cubic metre. The form accepts 0.000001 kg/m³ to 1500 kg/m³. Required: the tool does not calculate until every input is valid.
Example
The form opens with 870 kg/m³ as a worked example. It is an illustration, not a recommended value: replace it with your own figure.

Oil grade

What this means: Viscosity at 40 °C
Illustration: Viscosity at 40 °CFluid layers between a fixed and a moving plate, sliding past each other; Viscosity at 40 °C is the fluid’s resistance to that flow.ν₄₀Example: 220 cStViscosity at 40 °C
What it is
The kinematic viscosity of the oil at 40 °C, printed on the oil data sheet; the ISO VG grade is the nominal value at this temperature.
Units and format
Enter a number in cSt: centistokes (kinematic viscosity, 1 cSt = 1 mm²/s). The form accepts 1 cSt to 100000 cSt. Required: the tool does not calculate until every input is valid.
Example
The form opens with 220 cSt as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
Use kinematic viscosity in cSt (mm²/s), not dynamic viscosity in cP or mPa·s.
What this means: Viscosity at 100 °C
Illustration: Viscosity at 100 °CFluid layers between a fixed and a moving plate, sliding past each other; Viscosity at 100 °C is the fluid’s resistance to that flow.ν₁₀₀Example: 19 cStViscosity at 100 °C
What it is
The kinematic viscosity of the same oil at 100 °C, from its data sheet; with the 40 °C value it fixes how viscosity changes with temperature.
Units and format
Enter a number in cSt: centistokes (kinematic viscosity, 1 cSt = 1 mm²/s). The form accepts 0.5 cSt to 10000 cSt. Required: the tool does not calculate until every input is valid.
Example
The form opens with 19 cSt as a worked example. It is an illustration, not a recommended value: replace it with your own figure.
Get it right
It must be lower than the 40 °C value, and both values must come from the same oil.
What this means: Least viscosity the gears need at running tempe…
Illustration: Least viscosity the gears need at running temperatureFluid layers between a fixed and a moving plate, sliding past each other; Least viscosity the gears need at running temperature is the fluid’s resistance to that flow.νminExample: 50 cStLeast viscosity the gears need at running tem…
What it is
The least kinematic viscosity the gear or gearbox maker requires at the running temperature to keep a lubricating film on the teeth.
Units and format
Enter a number in cSt: centistokes (kinematic viscosity, 1 cSt = 1 mm²/s). The form accepts 1 cSt to 100000 cSt. Required: the tool does not calculate until every input is valid.
Example
The form opens with 50 cSt as a worked example. It is an illustration, not a recommended value: replace it with your own figure.

Method and formulas

  1. Heat = P (1 − η); equilibrium temperature = ambient + heat ÷ (h A); thermal limit, cooler duty and flow (as the gearbox heat balance tool).
  2. Running temperature = equilibrium temperature, or the maximum if a cooler is fitted to hold it there.
  3. Viscosity at the running temperature by the ASTM D341 relation through the 40 °C and 100 °C values (as the oil viscosity–temperature tool).
  4. Example: the oil settles at 70 °C where the oil is 51.702 cSt against 50 cSt needed.

Limitations

  • Steady state; start-up and intermittent duty run cooler.
  • Single housing coefficient; sun, enclosures and nearby heat sources change it.
  • Example values are illustrations. Replace them with values for your actual task.

Typical uses

  • Check a gearbox for a higher power or hotter site
  • Choose an oil grade for the running temperature
  • Decide whether a gearbox needs a cooler

Who it is for

  • Maintenance engineers
  • Lubrication engineers
  • Design engineers

What you get

  • Heat generated and equilibrium temperature
  • Thermal limit, cooler duty and oil flow
  • Viscosity at the running temperature

Interpreting the result

  • A shaft-mounted fan can double the housing coefficient, often removing the need for a cooler.

References

  • Machinery’s Handbook, 29th edition (Industrial Press, 2012), printed pp. 3339–3340, 2430–2436, 2329–2337. Topic reference; no source tables or recommended settings are reproduced.
  • ASTM D341 Viscosity–Temperature Charts for Liquid Petroleum Products

BIZOMAT tools are screening and decision-support utilities. Verify important financial, engineering, safety, legal or operational decisions using appropriate professional standards and your organisation’s approved data.

Open the Gearbox Oil Temperature and Grade Check (Heat Balance, Viscosity Hot) calculator